#add_cbecs_hvac_system(standard, system_type, zones) ⇒ Object
Adds the HVAC system as derived from the combinations of CBECS 2012 MAINHT and MAINCL fields.
Instance Method Details
#add_cbecs_hvac_system(standard, system_type, zones) ⇒ Object
Adds the HVAC system as derived from the combinations of CBECS 2012 MAINHT and MAINCL fields. Mapping between combinations and HVAC systems per www.nrel.gov/docs/fy08osti/41956.pdf Table C-31
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 |
# File 'lib/measures/create_typical_deer_building_from_model/resources/Model.hvac.rb', line 13 def add_cbecs_hvac_system(standard, system_type, zones) # the 'zones' argument includes zones that have heating, cooling, or both # if the HVAC system type serves a single zone, handle zones with only heating separately by adding unit heaters # applies to system types PTAC, PTHP, PSZ-AC, and Window AC heated_and_cooled_zones = zones.select { |zone| standard.thermal_zone_heated?(zone) && standard.thermal_zone_cooled?(zone) } heated_zones = zones.select { |zone| standard.thermal_zone_heated?(zone) } cooled_zones = zones.select { |zone| standard.thermal_zone_cooled?(zone) } cooled_only_zones = zones.select { |zone| !standard.thermal_zone_heated?(zone) && standard.thermal_zone_cooled?(zone) } heated_only_zones = zones.select { |zone| standard.thermal_zone_heated?(zone) && !standard.thermal_zone_cooled?(zone) } system_zones = heated_and_cooled_zones + cooled_only_zones # system type naming convention: # [ventilation strategy] [ cooling system and plant] [heating system and plant] case system_type when 'Baseboard electric' standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'Baseboard gas boiler' standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'Baseboard central air source heat pump' standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_zones) when 'Baseboard district hot water' standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_zones) when 'Direct evap coolers with baseboard electric' standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) when 'Direct evap coolers with baseboard gas boiler' standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) when 'Direct evap coolers with baseboard central air source heat pump' standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_zones) standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) when 'Direct evap coolers with baseboard district hot water' standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_zones) standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) when 'Direct evap coolers with forced air furnace' # Using unit heater to represent forced air furnace to limit to one airloop per thermal zone. standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) when 'Direct evap coolers with gas unit heaters' standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) when 'Direct evap coolers with no heat' standard.model_add_hvac_system(self, 'Evaporative Cooler', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) when 'DOAS with fan coil chiller with boiler' standard.model_add_hvac_system(self, 'DOAS', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Fan Coil', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones, zone_equipment_ventilation: false) when 'DOAS with fan coil chiller with central air source heat pump' standard.model_add_hvac_system(self, 'DOAS', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Fan Coil', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', zones, zone_equipment_ventilation: false) when 'DOAS with fan coil chiller with district hot water' standard.model_add_hvac_system(self, 'DOAS', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones, zone_equipment_ventilation: false) when 'DOAS with fan coil chiller with baseboard electric' standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones, zone_equipment_ventilation: false) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'DOAS with fan coil chiller with gas unit heaters' standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones, zone_equipment_ventilation: false) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'DOAS with fan coil chiller with no heat' standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones, zone_equipment_ventilation: false) when 'DOAS with fan coil air-cooled chiller with boiler' standard.model_add_hvac_system(self, 'DOAS', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') standard.model_add_hvac_system(self, 'Fan Coil', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled', zone_equipment_ventilation: false) when 'DOAS with fan coil air-cooled chiller with central air source heat pump' standard.model_add_hvac_system(self, 'DOAS', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') standard.model_add_hvac_system(self, 'Fan Coil', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled', zone_equipment_ventilation: false) when 'DOAS with fan coil air-cooled chiller with district hot water' standard.model_add_hvac_system(self, 'DOAS', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled', zone_equipment_ventilation: false) when 'DOAS with fan coil air-cooled chiller with baseboard electric' standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled', zone_equipment_ventilation: false) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'DOAS with fan coil air-cooled chiller with gas unit heaters' standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled', zone_equipment_ventilation: false) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'DOAS with fan coil air-cooled chiller with no heat' standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled', zone_equipment_ventilation: false) when 'DOAS with fan coil district chilled water with boiler' standard.model_add_hvac_system(self, 'DOAS', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', zones) standard.model_add_hvac_system(self, 'Fan Coil', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', zones, zone_equipment_ventilation: false) when 'DOAS with fan coil district chilled water with central air source heat pump' standard.model_add_hvac_system(self, 'DOAS', ht = 'AirSourceHeatPump', znht = nil, cl = 'DistrictCooling', zones) standard.model_add_hvac_system(self, 'Fan Coil', ht = 'AirSourceHeatPump', znht = nil, cl = 'DistrictCooling', zones, zone_equipment_ventilation: false) when 'DOAS with fan coil district chilled water with district hot water' standard.model_add_hvac_system(self, 'DOAS', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', zones) standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', zones, zone_equipment_ventilation: false) when 'DOAS with fan coil district chilled water with baseboard electric' standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'DistrictCooling', zones) standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones, zone_equipment_ventilation: false) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'DOAS with fan coil district chilled water with gas unit heaters' standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'DistrictCooling', zones) standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones, zone_equipment_ventilation: false) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'DOAS with fan coil district chilled water with no heat ' standard.model_add_hvac_system(self, 'DOAS', ht = nil, znht = nil, cl = 'DistrictCooling', zones) standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones, zone_equipment_ventilation: false) when 'DOAS with VRF' standard.model_add_hvac_system(self, 'DOAS', ht = 'Electricity', znht = nil, cl = 'Electricity', zones, air_loop_heating_type: 'DX', air_loop_cooling_type: 'DX') standard.model_add_hvac_system(self, 'VRF', ht = 'Electricity', znht = nil, cl = 'Electricity', zones) when 'DOAS with water source heat pumps fluid cooler with boiler' standard.model_add_hvac_system(self, 'DOAS', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Water Source Heat Pumps', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones, heat_pump_loop_cooling_type: 'FluidCooler', zone_equipment_ventilation: false) when 'DOAS with water source heat pumps cooling tower with boiler' standard.model_add_hvac_system(self, 'DOAS', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Water Source Heat Pumps', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones, heat_pump_loop_cooling_type: 'CoolingTower', zone_equipment_ventilation: false) when 'DOAS with water source heat pumps with ground source heat pump' standard.model_add_hvac_system(self, 'DOAS', ht = 'Electricity', znht = nil, cl = 'Electricity', zones, air_loop_heating_type: 'DX', air_loop_cooling_type: 'DX') standard.model_add_hvac_system(self, 'Ground Source Heat Pumps', ht = 'Electricity', znht = nil, cl = 'Electricity', zones, zone_equipment_ventilation: false) when 'DOAS with water source heat pumps district chilled water with district hot water' standard.model_add_hvac_system(self, 'DOAS', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', zones) standard.model_add_hvac_system(self, 'Water Source Heat Pumps', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', zones, zone_equipment_ventilation: false) # ventilation provided by zone fan coil unit in fan coil systems when 'Fan coil chiller with boiler' standard.model_add_hvac_system(self, 'Fan Coil', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones) when 'Fan coil chiller with central air source heat pump' standard.model_add_hvac_system(self, 'Fan Coil', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', zones) when 'Fan coil chiller with district hot water' standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones) when 'Fan coil chiller with baseboard electric' standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'Fan coil chiller with gas unit heaters' standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'Fan coil chiller with no heat' standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones) when 'Fan coil air-cooled chiller with boiler' standard.model_add_hvac_system(self, 'Fan Coil', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') when 'Fan coil air-cooled chiller with central air source heat pump' standard.model_add_hvac_system(self, 'Fan Coil', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') when 'Fan coil air-cooled chiller with district hot water' standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') when 'Fan coil air-cooled chiller with baseboard electric' standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'Fan coil air-cooled chiller with gas unit heaters' standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'Fan coil air-cooled chiller with no heat' standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') when 'Fan coil district chilled water with boiler' standard.model_add_hvac_system(self, 'Fan Coil', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', zones) when 'Fan coil district chilled water with central air source heat pump' standard.model_add_hvac_system(self, 'Fan Coil', ht = 'AirSourceHeatPump', znht = nil, cl = 'DistrictCooling', zones) when 'Fan coil district chilled water with district hot water' standard.model_add_hvac_system(self, 'Fan Coil', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', zones) when 'Fan coil district chilled water with baseboard electric' standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'Fan coil district chilled water with gas unit heaters' standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'Fan coil district chilled water with no heat ' standard.model_add_hvac_system(self, 'Fan Coil', ht = nil, znht = nil, cl = 'DistrictCooling', zones) when 'Forced air furnace' # includes ventilation, whereas residential forced air furnace does not. standard.model_add_hvac_system(self, 'Forced Air Furnace', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'Gas unit heaters' standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'PTAC with baseboard electric' standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = nil, cl = 'Electricity', system_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'PTAC with baseboard gas boiler' standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = nil, cl = 'Electricity', system_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'PTAC with baseboard district hot water' standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = nil, cl = 'Electricity', system_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_zones) when 'PTAC with gas unit heaters' standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = nil, cl = 'Electricity', system_zones) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'PTAC with electric coil' standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = 'Electricity', cl = 'Electricity', system_zones) # use 'Baseboard electric' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones) when 'PTAC with gas coil' standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = 'NaturalGas', cl = 'Electricity', system_zones) # use 'Baseboard electric' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones) when 'PTAC with gas boiler' standard.model_add_hvac_system(self, 'PTAC', ht = 'NaturalGas', znht = nil, cl = 'Electricity', system_zones) # use 'Baseboard gas boiler' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_only_zones) when 'PTAC with central air source heat pump' standard.model_add_hvac_system(self, 'PTAC', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', system_zones) # use 'Baseboard central air source heat pump' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_only_zones) when 'PTAC with district hot water' standard.model_add_hvac_system(self, 'PTAC', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', system_zones) # use 'Baseboard district hot water heat' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_only_zones) when 'PTAC with no heat' standard.model_add_hvac_system(self, 'PTAC', ht = nil, znht = nil, cl = 'Electricity', system_zones) when 'PTHP' standard.model_add_hvac_system(self, 'PTHP', ht = 'Electricity', znht = nil, cl = 'Electricity', system_zones) # use 'Baseboard electric' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones) when 'PSZ-AC with baseboard electric' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'Electricity', system_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'PSZ-AC with baseboard gas boiler' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'Electricity', system_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'PSZ-AC with baseboard district hot water' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'Electricity', system_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_zones) when 'PSZ-AC with gas unit heaters' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'Electricity', system_zones) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'PSZ-AC with electric coil' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = 'Electricity', cl = 'Electricity', system_zones) # use 'Baseboard electric' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones) when 'PSZ-AC with gas coil' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = 'NaturalGas', cl = 'Electricity', system_zones) # use 'Baseboard electric' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones) when 'PSZ-AC with gas boiler' standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'NaturalGas', znht = nil, cl = 'Electricity', system_zones) # use 'Baseboard gas boiler' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_only_zones) when 'PSZ-AC with central air source heat pump' standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'AirSourceHeatPump', znht = nil, cl = 'Electricity', system_zones) # use 'Baseboard central air source heat pump' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_only_zones) when 'PSZ-AC with district hot water' standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'DistrictHeating', znht = nil, cl = 'Electricity', system_zones) # use 'Baseboard district hot water' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_only_zones) when 'PSZ-AC with no heat' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) when 'PSZ-AC district chilled water with baseboard electric' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'DistrictCooling', system_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'PSZ-AC district chilled water with baseboard gas boiler' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'DistrictCooling', system_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'PSZ-AC district chilled water with gas unit heaters' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'DistrictCooling', system_zones) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'PSZ-AC district chilled water with electric coil' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = 'Electricity', cl = 'DistrictCooling', system_zones) # use 'Baseboard electric' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones) when 'PSZ-AC district chilled water with gas coil' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = 'NaturalGas', cl = 'DistrictCooling', system_zones) # use 'Baseboard electric' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones) when 'PSZ-AC district chilled water with gas boiler' standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', system_zones) # use 'Baseboard gas boiler' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_only_zones) when 'PSZ-AC district chilled water with central air source heat pump' standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'AirSourceHeatPump', znht = nil, cl = 'DistrictCooling', system_zones) # use 'Baseboard central air source heat pump' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_only_zones) when 'PSZ-AC district chilled water with district hot water' standard.model_add_hvac_system(self, 'PSZ-AC', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', system_zones) # use 'Baseboard district hot water' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_only_zones) when 'PSZ-AC district chilled water with no heat' standard.model_add_hvac_system(self, 'PSZ-AC', ht = nil, znht = nil, cl = 'DistrictCooling', cooled_zones) when 'PSZ-HP' standard.model_add_hvac_system(self, 'PSZ-HP', ht = 'Electricity', znht = nil, cl = 'Electricity', system_zones) # use 'Baseboard electric' for heated only zones standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_only_zones) # PVAV systems by default use a DX coil for cooling when 'PVAV with gas boiler reheat', 'Packaged VAV Air Loop with Boiler' # second enumeration for backwards compatibility with Tenant Star project standard.model_add_hvac_system(self, 'PVAV Reheat', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'Electricity', zones) when 'PVAV with central air source heat pump reheat' standard.model_add_hvac_system(self, 'PVAV Reheat', ht = 'AirSourceHeatPump', znht = 'AirSourceHeatPump', cl = 'Electricity', zones) when 'PVAV with district hot water reheat' standard.model_add_hvac_system(self, 'PVAV Reheat', ht = 'DistrictHeating', znht = 'DistrictHeating', cl = 'Electricity', zones) when 'PVAV with PFP boxes' standard.model_add_hvac_system(self, 'PVAV PFP Boxes', ht = 'Electricity', znht = 'Electricity', cl = 'Electricity', zones) when 'PVAV with gas heat with electric reheat' standard.model_add_hvac_system(self, 'PVAV Reheat', ht = 'Gas', znht = 'Electricity', cl = 'Electricity', zones) # all residential systems do not have ventilation when 'Residential AC with baseboard electric' standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = nil, cooled_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'Residential AC with baseboard gas boiler' standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = nil, cooled_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'Residential AC with baseboard central air source heat pump' standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = nil, cooled_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_zones) when 'Residential AC with baseboard district hot water' standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = nil, cooled_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_zones) when 'Residential AC with residential forced air furnace' standard.model_add_hvac_system(self, 'Residential Forced Air Furnace with AC', ht = nil, znht = nil, cl = nil, zones) when 'Residential AC with no heat' standard.model_add_hvac_system(self, 'Residential AC', ht = nil, znht = nil, cl = nil, cooled_zones) when 'Residential heat pump' standard.model_add_hvac_system(self, 'Residential Air Source Heat Pump', ht = 'Electricity', znht = nil, cl = 'Electricity', zones) when 'Residential heat pump with no cooling' standard.model_add_hvac_system(self, 'Residential Air Source Heat Pump', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'Residential forced air furnace' standard.model_add_hvac_system(self, 'Residential Forced Air Furnace', ht = 'NaturalGas', znht = nil, cl = nil, zones) when 'VAV chiller with gas boiler reheat' standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'Electricity', zones) when 'VAV chiller with central air source heat pump reheat' standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'AirSourceHeatPump', znht = 'AirSourceHeatPump', cl = 'Electricity', zones) when 'VAV chiller with district hot water reheat' standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'DistrictHeating', znht = 'DistrictHeating', cl = 'Electricity', zones) when 'VAV chiller with PFP boxes' standard.model_add_hvac_system(self, 'VAV PFP Boxes', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'Electricity', zones) when 'VAV chiller with gas coil reheat' standard.model_add_hvac_system(self, 'VAV Gas Reheat', ht = 'NaturalGas', ht = 'NaturalGas', cl = 'Electricity', zones) when 'VAV chiller with no reheat with baseboard electric' standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'VAV chiller with no reheat with gas unit heaters' standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'VAV chiller with no reheat with zone heat pump' standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones) # Using PTHP to represent zone heat pump to limit to one airloop per thermal zone. standard.model_add_hvac_system(self, 'PTHP', ht = 'Electricity', znht = nil, cl = 'Electricity', zones) when 'VAV air-cooled chiller with gas boiler reheat' standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') when 'VAV air-cooled chiller with central air source heat pump reheat ' standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'AirSourceHeatPump', znht = 'AirSourceHeatPump', cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') when 'VAV air-cooled chiller with district hot water reheat' standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'DistrictHeating', znht = 'DistrictHeating', cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') when 'VAV air-cooled chiller with PFP boxes' standard.model_add_hvac_system(self, 'VAV PFP Boxes', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') when 'VAV air-cooled chiller with gas coil reheat' standard.model_add_hvac_system(self, 'VAV Gas Reheat', ht = 'NaturalGas', ht = 'NaturalGas', cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') when 'VAV air-cooled chiller with no reheat with baseboard electric' standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'VAV air-cooled chiller with no reheat with gas unit heaters' standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'VAV air-cooled chiller with no reheat with zone heat pump' standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones, chilled_water_loop_cooling_type: 'AirCooled') # Using PTHP to represent zone heat pump to limit to one airloop per thermal zone. standard.model_add_hvac_system(self, 'PTHP', ht = 'Electricity', znht = nil, cl = 'Electricity', zones) when 'VAV district chilled water with gas boiler reheat' standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'DistrictCooling', zones) when 'VAV district chilled water with central air source heat pump reheat' standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'AirSourceHeatPump', znht = 'AirSourceHeatPump', cl = 'DistrictCooling', zones) when 'VAV district chilled water with district hot water reheat' standard.model_add_hvac_system(self, 'VAV Reheat', ht = 'DistrictHeating', znht = 'DistrictHeating', cl = 'DistrictCooling', zones) when 'VAV district chilled water with PFP boxes' standard.model_add_hvac_system(self, 'VAV PFP Boxes', ht = 'NaturalGas', znht = 'NaturalGas', cl = 'DistrictCooling', zones) when 'VAV district chilled water with gas coil reheat' standard.model_add_hvac_system(self, 'VAV Gas Reheat', ht = 'NaturalGas', ht = 'NaturalGas', cl = 'DistrictCooling', zones) when 'VAV district chilled water with no reheat with baseboard electric' standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'VAV district chilled water with no reheat with gas unit heaters' standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', zones) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'VAV district chilled water with no reheat with zone heat pump' standard.model_add_hvac_system(self, 'VAV No Reheat', ht = 'NaturalGas', znht = nil, cl = 'DistrictCooling', zones) # Using PTHP to represent zone heat pump to limit to one airloop per thermal zone. standard.model_add_hvac_system(self, 'PTHP', ht = 'Electricity', znht = nil, cl = 'Electricity', zones) when 'VRF' standard.model_add_hvac_system(self, 'VRF', ht = 'Electricity', znht = nil, cl = 'Electricity', zones) when 'Water source heat pumps fluid cooler with boiler' standard.model_add_hvac_system(self, 'Water Source Heat Pumps', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones, heat_pump_loop_cooling_type: 'FluidCooler') when 'Water source heat pumps cooling tower with boiler' standard.model_add_hvac_system(self, 'Water Source Heat Pumps', ht = 'NaturalGas', znht = nil, cl = 'Electricity', zones, heat_pump_loop_cooling_type: 'CoolingTower') when 'Water source heat pumps with ground source heat pump' standard.model_add_hvac_system(self, 'Ground Source Heat Pumps', ht = 'Electricity', znht = nil, cl = 'Electricity', zones) when 'Water source heat pumps district chilled water with district hot water' standard.model_add_hvac_system(self, 'Water Source Heat Pumps', ht = 'DistrictHeating', znht = nil, cl = 'DistrictCooling', zones) when 'Window AC with baseboard electric' standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'Electricity', znht = nil, cl = nil, heated_zones) when 'Window AC with baseboard gas boiler' standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'Window AC with baseboard central air source heat pump' standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'AirSourceHeatPump', znht = nil, cl = nil, heated_zones) when 'Window AC with baseboard district hot water' standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) standard.model_add_hvac_system(self, 'Baseboards', ht = 'DistrictHeating', znht = nil, cl = nil, heated_zones) when 'Window AC with forced air furnace' standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) standard.model_add_hvac_system(self, 'Forced Air Furnace', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'Window AC with unit heaters' standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) standard.model_add_hvac_system(self, 'Unit Heaters', ht = 'NaturalGas', znht = nil, cl = nil, heated_zones) when 'Window AC with no heat' standard.model_add_hvac_system(self, 'Window AC', ht = nil, znht = nil, cl = 'Electricity', cooled_zones) else return false end return true end |